Electrical Control Panel
1. Everything in the van is dead.
Check the supply lead, supply from the house socket, RBCO in the main panel.

2. The Lights work but nothing else.
Check MCB1, MCB3 and MCB4.

3. The Pump is not working.
The water pump is protected by a thermal overload in the control panel.
If this trips it will have to be reset by pressing the blue pushbutton on the unit. There is a small flag on the overload which shows yellow if the overload has tripped.
If the thermal overload has not tripped the capacitor may have failed and will need to be replaced (see the Replacement Parts and Maintenance page).

4. When the pump pushbutton is pressed the contractor operates but the pump will not run.
Check MCB3.

5. The lights are not working.
Check MCB2.

6. The Heater and Sockets are not working.
Check MCB1.